5069 if8 manual - 2 Rockwell Automation Publication 5069-IN001D-EN-P - December 2021 Compact 5000 I/O Field Potential Distributor Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain

 
ControlLogix 8 Point A/I Module. Lifecycle status: ACTIVE. Find a Distributor. Find Product Drawings. Find Firmware & Downloads. Add to BoM. Get Support. 1756-IF8. Find a Distributor.. Ncaa football 14 rosters 2022 23

Default The Allen-Bradley 5069 Compact 5000 series 5069-IF8 module is an analog input module. It is an 8-channel current/voltage input module. It offers differential, non-isolated inputs that are able to connect with different input devices. The module comes with 16-bit resolution and it has an update time of 1 millisecond.5069-AENTR, 5069-AENTRK(1) (1) A catalog number followed by a “K” indicates a conformal coating option. 10 Mbps 100 Mbps 1 Gbps Yes Yes Yes No Explicit Implicit Yes 5069-AEN2TR 10 Mbps 100 Mbps 1 Gbps Yes Yes Yes No Not Supported Yes IMPORTANT Protected Mode is only available with the 5069-AENTR adapter. The 5069-AEN2TR adapter does not ...Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available. These modules are the ideal ...Catalog Number 5069-OW16 The 5069-OW16 digital 16-point normally open relay output module drives output devices. The data sent to the module from a Logi x 5000™ controller and the state of some Compact 5000™ I/O input modules determines the 5069-OW16 module behavior. Compact 5000 I/O modules use the Producer/Consumer communication mo del."The 5069-IF8 is a Compact 5000 I/O module. This module is an Eight (8) channels analog input module dedicated for Current and Voltage signals. This module is not compatible for direct integration with RTD or Thermocouple sensors. However, when compared to universal input modules such as the 5069-IY4, the 5069-IF8 has more input channels.5069-IF8: Manufacturer: Allen-Bradley / Rockwell Automation: Description: Allen-Bradley 5069-IF8 5069 Compact I/O 8-Ch Current/Voltage Input Module: Full Description: Allen Bradley 5069-IF8 5069 CompactLogix Compact I/O 8 Channel Current/Voltage Analog Input Module: UPC / GTIN: 00885630530062: Status: Current ProductLifecycle status: ACTIVE. Find a Distributor. to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Register this Product. Add to BoM. Add to Repair Quote. Get Support. 5069-L320ER. User Manual. Original Instructions. 5000 Series Analog I/O Modules in Logix5000 Control Systems. Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8. 5069-RTB18-SCREW RTB only: 0.4 Nm (3.5 lbin) Overvoltage protection, max. ±32V DC. Short circuit detection. Voltage mode only – output electronically limited to 16 mA or less. Data format. IEEE 32-bit floating point. Wire category. 2 - shielded input ports, 2 - power ports, 1 wire per terminal for each signal port.The 5069-IY4, and 5069-IY4K analog 4-channel universal input module offers differential and single-ended, non-isolated input channels and Thermocouple and RTD input channels that can operate in a wide range of applications.5069-AENTR, 5069-AENTRK(1) (1) A catalog number followed by a “K” indicates a conformal coating option. 10 Mbps 100 Mbps 1 Gbps Yes Yes Yes No Explicit Implicit Yes 5069-AEN2TR 10 Mbps 100 Mbps 1 Gbps Yes Yes Yes No Not Supported Yes IMPORTANT Protected Mode is only available with the 5069-AENTR adapter. The 5069-AEN2TR adapter does not ... I have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. Rick2 Rockwell Automation Publication 5069-IN004D-EN-P - December 2021 Compact 5000 Digital 16-point Sinking Input Modules Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or ...Product Drawings. Offering a powerful range of product drawing tools to help you design & apply our products. Available on-line or for download, our tools help you access information while in the office or on the go. Technical Documentation Center. FAQs. DDSView and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 29 describes the I/O Status indicator on 5069 Compact I/O analog output modules.Literature Library | Rockwell AutomationOur Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available. These modules are the ideal ... DefaultLifecycle status: ACTIVE. Find a Distributor. to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Register this Product. Add to BoM. Add to Repair Quote. Get Support. 5069-L320ER. I saw this thread and thought "there's no way in the world a 5069-IF8 doesn't support 3 wire transmitters" and figured I'd find a working example onsite to prove it, then post back. I then promptly forgot about it. But I remembered this morning, and yes, I have wired 2, 3 and 4 wire 4-20mA transmitters to a 5069-IF8 and it works just fine.Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User InformationTechnical Data. 5069-TD001. Find more technical documentation for this product in the Technical Documentation Center. TYPE. Technical Data. PUBLICATION NUMBER. 5069-TD001.5069-RTB18-SCREW RTB only: 0.4 Nm (3.5 lbin) Overvoltage protection, max. ±32V DC. Short circuit detection. Voltage mode only – output electronically limited to 16 mA or less. Data format. IEEE 32-bit floating point. Wire category. 2 - shielded input ports, 2 - power ports, 1 wire per terminal for each signal port.Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User InformationThe 5069 analog I/O modules for use with this controller are 5069-IF8 (differential current/voltage) and 5069-IY4. The IY4 is able to take thermocouple and RTD inputs along with diff current and voltage. The user manual ( Compact 5000 I/O Analog Modules User Manual) for both of these modules state that 3-wire analog devices " are not supported ...Literature Library | Rockwell AutomationFrom the manual. Flashing red One of the following conditions exist: • A module firmware update is in progress. • A module firmware update attempt failed. • The device has experienced a recoverable fault. • A connection to the module has timed out. Complete one of the following: • Let the firmware update progress complete.Rockwell new Compact Logix I/O. Hello, Rockwell is out with new compactlogix series 5069 series I/O. I have the 2017 AutoCAD electrical, but this series does not exist in the PLC database. I can use the PLC database editor to start entering the cards that I need but, I am wondering if anything has already been created for autocad electrical.Literature Library | Rockwell Automation (1) Catalog numbers 5069-IF8 and 5069-IY4 support differential inputs only. Conversion Module Catalog Number Conversion Module Description 1746-NI8 5069-IF8 1492-CM1746-MO5 High Resolution (8) Analog Input Module 1746-NI4 5069-IY4 1492-CM1746-MO6 High Resolution (4) Analog Input Module Rockwell Product Catalog. Packaged Solutions (148) Product Selection Wizards (6) Condition Monitoring (10) Condition Sensors, Switches and Controls (19) Connection Systems (13) Control Circuit and Load Protection (81) Drives (70) Hazardous Locations (2)User Manual. Original Instructions. 5000 Series Analog I/O Modules in Logix5000 Control Systems. Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8. I have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. Rick1746 SLC I/O Analog Modules. Rockwell Automation announces that a number of Bulletin 1746 I/O modules are discontinued and no longer available for sale. Customers are encouraged to migrate to our Compact 5000™ I/O modules used with the Logix control platform.Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available. These modules are the ideal ...Module, Distributed I/O, 8 Channel, Analog Input, HART. Lifecycle status: ACTIVE. Find a Distributor. to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Register this Product. Add to BoM. Get Support. 5094-IF8IH.Get Support 5069-IF8 Find a Distributor Technical Specifications For full product specifications, please see the product catalog. Documentation Find all available product literature for this product in the Literature Library results.Use your product. POINT I/O 4 Channel IO-Link Master Module User Manual POINT I/O ASCII Modules User Manual POINT I/O DeviceNet Adapter User Manual POINT I/O EtherNet/IP Adapter Module User Manual POINT I/O and ArmorPOINT I/O 2 Port EtherNet/IP Adapters (1734-AENTR, 1738-AENTR, Series A) User Manual POINT I/O and ArmorPOINT I/O Dual Port ...Use your product. Compact I/O ASCII Module User Manual Compact I/O BOOLEAN Module User Manual Compact I/O BOOLEAN Module Reference Manual Compact High-speed Counter Module User Manual 1769-IR6 RTD/Resistance Input Module User Manual 1769-IT6 Thermocouple/mV Input Module User Manual.User ManualOriginal Instructions Compact 5000 I/O Analog Modules Catalog Numbers 5069-IF8, 5069-IY4, 5069-IY4K, 5069-OF4, 5069-OF4K, 5069-OF8 2Rockwell Automation Publication 5069-UM005C-EN-P - January 2022 Compact 5000 I/O Analog Modules User Manual Important User Information5069-IF8 FieldPowerOff = 1. Got a trouble call with a 5069-IF8 module that has all the channels flashing red. Upon logging in, I see that each channel is faulted with the FieldPowerOff bit set to 1. I had them verify the SA power is good, which it is, and another 5069-IF8 module 2 slots down is functioning fine, so SA power appears to be good.Catalog Numbers 5069-IB8S, 5069-IB8SK The 5069-IB8S and 5069-IB8SK modules are 8-point safety sinking input modules. The modules provide safety I/O on a safety-control network that meets the requirements up to and including SIL CL 3, and PLe, Cat. 4 as defined in IEC 61508, IEC 61511, IEC 62061, and ISO 13849-1. Technical Data. 5069-TD001. Find more technical documentation for this product in the Technical Documentation Center. TYPE. Technical Data. PUBLICATION NUMBER. 5069-TD001.Literature Library | Rockwell Automation2 Rockwell Automation Publication 5069-IN013I-EN-P - March 2022 CompactLogix 5380 Controllers Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintain5069-IF8 Installation Download. 5069-IY4, 5069-IY4K Installation ... Compact 5000 I/O High-Speed Counter Module User Manual Looking for more? Download. CompactLogix ...Compact I/O 5069 Número de catálogo 5069-IF8 Instrucciones de instalación Descripción general del producto El módulo de entradas analógicas de voltaje/corriente de 8 ca nales 5069-IF8 ofrece canales de entrada diferenciales, no aislado s, que pueden conectarse con dispositivos de entrada de corriente o de voltaje. Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available.Rockwell new Compact Logix I/O. Hello, Rockwell is out with new compactlogix series 5069 series I/O. I have the 2017 AutoCAD electrical, but this series does not exist in the PLC database. I can use the PLC database editor to start entering the cards that I need but, I am wondering if anything has already been created for autocad electrical.5069 Compact I/O 16 Channel 24VDC Sink Input Module. Lifecycle status: ACTIVE. Find a Distributor. Learn how to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Add to BoM. Get Support. 5069-IB16. Find a Distributor.Hi, We are working with AB-CompactLogix L32E controller including Compact I/O 1769-IF8 analog input module. We have been configure 1769-IF8 module as engineering units (Min 4000 to Max 20000). At the analog input side we have connected Non-Loop powered 4-20mA Amplifier as per 1769-IF8 wiring drawing (Iout+ to Iin+ and Iout- to V/I in-). The amplifier successfully generate the 4-20mA signal ...Note: The selected IO Product needs the Terminal kits 5069-RTB18-SCREW or 5069-RTB18-SPRING. Terminal kits are pre-packed in a pack of 5pcs I/O Modules Category: Analog Type: Input No of Inputs/Outputs: 8 Catalog Number Catalog Number: 5069 Compact I/O 8 Channel Voltage/Current Analog Input Module NoteHi, We are working with AB-CompactLogix L32E controller including Compact I/O 1769-IF8 analog input module. We have been configure 1769-IF8 module as engineering units (Min 4000 to Max 20000). At the analog input side we have connected Non-Loop powered 4-20mA Amplifier as per 1769-IF8 wiring drawing (Iout+ to Iin+ and Iout- to V/I in-). The amplifier successfully generate the 4-20mA signal ...View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Table 33 - 5069-IY4 Module - Configuration Tags Name Size Definition Chxx.HighSignal REAL One of four points used in... Allen-Bradley 5069-IF8 User Manual Download Operation & user’s manual of Allen-Bradley 5069-IF8 I/O Systems for Free or View it Online on All-Guides.com. This version of Allen-Bradley 5069-IF8 Manual compatible with such list of devices, as: 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8Lifecycle status: ACTIVE. Find a Distributor. to avoid the risks of unauthorized and counterfeit products. Find Product Drawings. Register this Product. Add to BoM. Add to Repair Quote. Get Support. 5069-L320ER.Nov 24, 2018 · I have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. Rick • The 5069-IA16 module inputs use a shared common. The inputs have a return through internal module circuitry to the SA (–) terminal on the SA Power RTB. • If you install modules in a 5069 Compact I/O system that use AC SA power and DC SA power, you must install them on separate SA Power buses. 1 Publication 1769-UM002B-EN-P - July 2005 Summary of Changes The 1769-IF8, -OF8C, and -OF8V modules have been added to this manual since the last printing. 2 Rockwell Automation Publication 5069-IN001D-EN-P - December 2021 Compact 5000 I/O Field Potential Distributor Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or maintainView and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Appendix A Troubleshoot Your Module Table 29 describes the I/O Status indicator on 5069 Compact I/O analog output modules.2 Rockwell Automation Publication 5069-TD001D-EN-P - October 2016 5069 Compact I/O Modules Specifications Summary of Changes Changes to the publication are listed in this table. Digital I/O Modules Topic Page Addition of information for the 5069-IA16 digital input module 3 Addition of information for the 5069-OA16 digital output module 18 This manual shows how to monitor and handle major and minor controller faults. The manual also provides lists of major, minor, and I/O fault codes to use to troubleshoot the system. This manual is one of a set of related manuals that show common procedures for programming and operating Logix 5000 controllers. The 5069-IY4 has an input resolution of 15-bits plus sign and 16 bits for voltage; 16-bits for current, RTD and Thermocouple. Is the Thermocouple input provided with CJC sensors? Yes. Two (2) CJC sensors are available. What is the scan time of the 5069-IY4? The 5069-IY4 has rated scan time of 625 µs per channel and 2.5 ms per group.Issue 3: Updated ratings on 5069-IB6F3W and 5069-OF8 to 900mA and 250mA respectively, added models 5069-IA16, 5069-OB8, 5069- OA16 and 5069-OW16 and updated drawings. Issue 4: Update was to clarify the spacings verdict in Clause 13 from the IEC 60079-15 standard. Access technical specifications, installation instructions, and manuals for Allen-Bradley 5069 Compact 5000 I/O and chassis-based communication modules. Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual. Important User Information 2 Rockwell Automation Publication 5069-IN015C-EN-P - December 2021 Compact 5000 Digital 16-point 120/240V AC Input Module Installation Instructions ATTENTION: Read this document and the documents listed in the Additional Resources section about installation, configuration and operation of this equipment before you install, configure, operate or ...4 Rockwell Automation Publication 5069-TD001G-EN-P - June 2018 Compact 5000 I/O Modules and EtherNet/IP Adapters 5069-IA16 Digital 16-point 120/240V AC Input Module This figure shows a wiring diagram for the 5069-IA16 module. 5069-IA16 Wiring Diagram Input Channel 0 Input Channel 1 Input Channel 2 Input Channel 3 Input Channel 4 Input Channel 5 ... Catalog Numbers 5069-AENTR, 5069-AENTRK, 5069-AEN2TR The Compact 5000™ I/O EtherNet/IP adapters perform the following functions: • Facilitate high-speed data transfer across an EtherNet/IP network between Compact 5000 I/O modules and a Logix 5000™controller. • Provide system-side and field-side power to Compact 5000 I/O modules.Rockwell Product Catalog. Packaged Solutions (148) Product Selection Wizards (6) Condition Monitoring (10) Condition Sensors, Switches and Controls (19) Connection Systems (13) Control Circuit and Load Protection (81) Drives (70) Hazardous Locations (2) Our Bulletin 5069 Compact 5000™ I/O modules provide high-performance control in a compact design, and expand the performance capabilities of the Logix platform. They are the local I/O modules in a CompactLogix™ 5380, Compact GuardLogix® 5380, or CompactLogix 5480 system and safety options are available.Literature Library | Rockwell Automation2 Rockwell Automation Publication 5069-TD001D-EN-P - October 2016 5069 Compact I/O Modules Specifications Summary of Changes Changes to the publication are listed in this table. Digital I/O Modules Topic Page Addition of information for the 5069-IA16 digital input module 3 Addition of information for the 5069-OA16 digital output module 18Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual Original Instructions IMPORTANT This manual has been replaced by the Compact 5000 I/O Analog Modules User Manual, publication 5069-UM005. Rockwell Product Catalog. Packaged Solutions (148) Product Selection Wizards (6) Condition Monitoring (10) Condition Sensors, Switches and Controls (19) Connection Systems (13) Control Circuit and Load Protection (81) Drives (70) Hazardous Locations (2) 5069-IF8: Manufacturer: Allen-Bradley / Rockwell Automation: Description: Allen-Bradley 5069-IF8 5069 Compact I/O 8-Ch Current/Voltage Input Module: Full Description: Allen Bradley 5069-IF8 5069 CompactLogix Compact I/O 8 Channel Current/Voltage Analog Input Module: UPC / GTIN: 00885630530062: Status: Current ProductCatalog Number 5069-OW16 The 5069-OW16 digital 16-point normally open relay output module drives output devices. The data sent to the module from a Logi x 5000™ controller and the state of some Compact 5000™ I/O input modules determines the 5069-OW16 module behavior. Compact 5000 I/O modules use the Producer/Consumer communication mo del. Catalog Numbers 5069-OF4, 5069-OF4K, 5069-OF8 The 5069-OF4, 5069-OF4K, and 5069-OF8 analog current/voltage output modules convert digital values to analog signals. The module offers non-isolated output channels that can connect to current or voltage input devices, and the module channels support multiple ranges for each output type. Nov 24, 2018 · I have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. Rick User Manual. Original Instructions. 5000 Series Analog I/O Modules in Logix5000 Control Systems. Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8.

The 5069-FPD field potential distributor breaks field-side power distribution in a CompactLogix™ 5380, CompactLogix 5480, or Compact GuardLogix® 5380 control system or a Compact 5000™ I/O system and creates a new SA power bus to the right of the field potential distributor from which Compact 5000 I/O modules can draw current. . Fountains at chimney rock virtual tours available

5069 if8 manual

The 5069 analog I/O modules for use with this controller are 5069-IF8 (differential current/voltage) and 5069-IY4. The IY4 is able to take thermocouple and RTD inputs along with diff current and voltage. The user manual ( Compact 5000 I/O Analog Modules User Manual) for both of these modules state that 3-wire analog devices " are not supported ...Australian RCM. IECEx Scheme. ATEX. This product was certified with the above certifications as of 2023-09-04. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries. Jul 5, 2023 · Our free 2-year warranty makes every Radwell purchase a dependable, reliable investment in your company's future. Warranty Terms and Conditions. If you need a specific series relating to 5069-IF8, we probably have it. Please call or email us with your request. Order toll free: 800.884.5500. Order international: +1 609.288.9393. View and Download Allen-Bradley 5069-IF8 user manual online. Analog I/O Modules 5000 Series in Logix5000 Control Systems. 5069-IF8 i/o systems pdf manual download. Also for: 5069-of4, 5069-iy4, 5069-of8. Literature Library | Rockwell AutomationI have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. RickAnalog I/O Module Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 High-speed Counter Module Catalog Number 5069-HSC2xOB4 Serial Module Catalog Number 5069-SERIAL Field Potential Distributor Catalog Number 5069-FPD Address Reserve Module Catalog Number 5069-ARM EtherNet/IP Adapter Catalog Number 5069-AENTR, 5069-AEN2TRI have the same issue on 2 installs. 5069-IQ16 24vdc input at reference does not initiate the input. Re-routing of the wiring solved the issue. 5069-IF8 input properly shielded had to be re-routed not to induce a fault on the card. I have discontinued using the 5069 i/o until AB solves the issue. RickCatalog Number 5069-OW16 The 5069-OW16 digital 16-point normally open relay output module drives output devices. The data sent to the module from a Logi x 5000™ controller and the state of some Compact 5000™ I/O input modules determines the 5069-OW16 module behavior. Compact 5000 I/O modules use the Producer/Consumer communication mo del. The 5069-IF8 analog 8-channel current/voltage input module offers non-isolated input channels that can connect to current or voltage input devices. The module supports multiple ranges for each input type. Compact 5000TM I/O modules use the Producer/Consumer communication model.The 5069-IY4, and 5069-IY4K analog 4-channel universal input module offers differential and single-ended, non-isolated input channels and Thermocouple and RTD input channels that can operate in a wide range of applications.Catalog Numbers 5069-IF8, 5069-IY4, 5069-OF4, 5069-OF8 User Manual Original Instructions IMPORTANT This manual has been replaced by the Compact 5000 I/O Analog Modules User Manual, publication 5069-UM005.I/O Systems Allen-Bradley 5069-IF8 User Manual. Analog i/o modules 5000 series in logix5000 control systems (166 pages) I/O Systems Allen-Bradley 1756-IF8I User Manual. High resolution analog i/o modules (226 pages) I/O Systems Allen-Bradley 1734-IE2C Installation Instructions Manual..